7-20
Options

Accu-Stop Option

Figure 7.16 Accu-Stop Option Sequence of Operation
100%
Motor
Speed
Slow
Speed
Push Buttons
Start
Closed
Open
Stop
Closed
Open
Accu-Stop
Closed
Open
Auxiliary
Contacts
Normal
Up-to-speed
When Accu-Stop push button is closed, start/stop function is disabled.
ATTENTION: The user is responsible for
determining which stopping mode is best suited to the
!
application and will meet applicable standards for
operator safety on a particular machine.
Run
Start
Time (seconds)
If Stopping Current is set to 0%.
Braking
Slow Speed
Braking/Coast
Slow Speed
Accu-Stop