n Connect on/off thermostat
Tk
The boiler is suitable for connection to a 2 wire on/off room thermostat.
Tk
4 Install the regulator in the reference room (generally the living
4 Connect the 2 wire 24V room thermostat to the On/off-OT
4 Connect the power stealing thermostat to the On/off-OT terminals
T001590-B
4.8.6.
Ba
Ba
An outside sensor can be connected to the Tout terminals of the
connector. Where there is an on/off thermostat controller, the boiler
will control the temperature with the set point of the internal heating
curve.
T001591-B
n Heating curve setting
If an outside temperature sensor is connected, it is possible to adapt
the heating curve. The setting can be modified using parameters
p1, p"5, p"6 and p"7.
F
10
20
T000441-B
ON/OFF room thermostat
room).
terminals of the connector.
of the connector.
If a room thermostat with an anticipation element is used,
this must be converted using parameter p5.
Connecting the outside temperature
sensor
Outside sensor
A OpenTherm controller can also use this outside sensor.
The heating curve required must then be set on the
controller.