5. Start-up
54
Heat demand 5 t D
Heat demand stopped
1 : Fan ON
1 : Post-ventilation
" : Boiler is igniting 5 : Burner stop
6 : Post-circulation of the pump
3 : Heating System 0 : Standby
In addition to 0, in STAND-BY the display normally shows the water
pressure and the symbols 5 t D , 5 t H and N.
Error during the start-up procedure:
4 No information is shown on the display:
- Check the mains supply voltage
- Check the main fuses
- Check the fuses on the control panel:
(F1 = 6,3 AT, F2 = 2 AT)
- Check the connection of the mains lead to the connector X1 in
the instrument box
4 A fault is indicated on the display by the fault symbol c and a
flashing fault code.
- The meaning of the error codes is given in the error table.
- Press for 3 seconds on key J to restart the boiler.
If the economy setting (eco setting) is on, then, after central
heating operation, the boiler will not start to run for hot tap
water production.