Resetting The Automatic Maintenance Message; Dealing With The Next Maintenance Message And Starting The New Maintenance Period - REMEHA Quinta Pro 30 Installation And Service Manual

Wall-hung gas condensing boilers
Hide thumbs Also See for Quinta Pro 30:
Table of Contents

Advertisement

Quinta Pro 45 - 65 - 90 - 115
1x
5x
...x
...x
3x
080310 - 123157-AA
7.2.1.
A service message on the boiler display must be reset by a qualified
installer after the maintenance service has been carried out using the
relevant service set. To do this, proceed as follows:
1. When the maintenance message is displayed, press key J1
2. Use keys [-] or [+] to input the installer code 0012.
3. Confirm using key S. The maintenance message is reset. The
T001629-A
7.2.2.
For an interim service it is advisable to read out in the boiler service
menu what maintenance service should be carried out. Use the
indicated Remeha service sets (A, B or C). This service message
must be prevented by carrying out a reset. Start the next service
interval. To do this, proceed as follows:
1. Press the two keys f simultaneously and then key [+] until the
2. Press the S key. hr and the number of hours of boiler
3. Press key [+] several times until K flashes on the menu bar.
4. Press the S key. c0de appears on the display.
5. Use keys [-] or [+] to input the installer code 0012.
6. Confirm using key S.
7. Press key [+] several times until 5c[B is displayed with B (for
8. Press the [+] key a second time. cl appears on the display.
9. Press the S key. cl[0 is displayed with 0 flashing.
10.Press key [+] to modify the value to 1.
11.Confirm using key S. The new maintenance period begins.
12.Press 3 times on key > to return to the current operating mode.
T001630-A
Resetting the automatic maintenance
message
time. c0de appears on the display.
display returns to the current operating mode.
Dealing with the next maintenance
message and starting the new maintenance
period
symbol \ flashes on the menu bar.
operation 3600 (for example) are displayed alternately.
example) flashing To determine the best time to carry out
maintenance, the boiler is fitted with a single automatic
maintenance indicator.
After a service complete the checklist ( ¼ "Checklist
for periodic inspection and maintenance", page 81.