Event
Type
modem
voice-start
PTT
voice-end

14.4.1 SIT Event Detection

The device can detect and report the following Special Information Tones (SIT) types from
the PSTN:
SIT-NC (No Circuit found)
SIT-IC (Operator Intercept)
SIT-VC (Vacant Circuit - non-registered number)
SIT-RO (Reorder - System Busy)
There are additional three SIT tones that are detected as one of the above SIT tones:
The NC* SIT tone is detected as NC
The RO* SIT tone is detected as RO
The IO* SIT tone is detected as VC
The device can map these SIT tones to a Q.850 cause and then map them to SIP 5xx/4xx
responses,
SITQ850CauseForIC, SITQ850CauseForVC, and SITQ850CauseForRO.
Table 14-2: Special Information Tones (SITs) Reported by the device
Special
Description
Information
Tones (SITs)
Name
NC1
No circuit found
IC
Operator intercept
VC
Vacant circuit (non
registered number)
RO1
Reorder (system
busy)
NC*
-
RO*
-
IO*
-
The following example shows a SIP INFO message sent by the device to a remote
application server notifying it that SIT detection has been detected:
User's Manual
Subtype
using
the
parameters
First Tone
Frequency
Duration
(Hz)
985.2
913.8
985.2
913.8
913.8
985.2
913.8
Mediant 800B Gateway & E-SBC
Description and Required Configuration
than 0.
- or -
Set the IsFaxUsed parameter to 0 and the
FaxTransportMode parameter to any value other
than 0.
Set the VxxModemTransportType parameter to 3.
Set the EnableDSPIPMDetectors parameter to 1.
SITQ850Cause,
Second Tone
Frequency
Duration
(ms)
(Hz)
380
1428.5
274
1370.6
380
1370.6
274
1428.5
380
1370.6
274
1370.6
380
1428.5
202
SITQ850CauseForNC,
Third Tone
Frequency
Duration
(ms)
(Hz)
(ms)
380
1776.7
380
274
1776.7
380
274
1776.7
380
380
1776.7
380
380
1776.7
380
380
1776.7
380
274
1776.7
380
Document #: LTRT-10298