Note:
All LAN ports have the same MAC address, which is the MAC address of the
device.
Each Ethernet port must have a unique VLAN ID in scenarios where the ports are
connected to the same switch.
The following procedure describes how to configure Ethernet ports through the Web
interface. You can also configure it through ini file (PhysicalPortsTable) or CLI (configure
network > physical-port).
To configure the physical Ethernet ports:
1.
Open the Physical Ports table (Setup menu > IP Network tab > Core Entities folder >
Physical Ports).
2.
Select a port that you want to configure, and then clicking Edit; the following dialog
box appears:
3.
Configure the port according to the parameters described in the table below.
4.
Click Apply, and then save your settings to flash memory.
Table 12-2: Physical Ports Table Parameter Descriptions
Parameter
General
Index
Name
port
[PhysicalPortsTable_Port]
Description
port-description
[PhysicalPortsTable_PortDescription]
Mode
mode
[PhysicalPortsTable_Mode]
Version 7.2
(Read-only) Displays the index number for the table row.
(Read-only) Displays the Ethernet port number. See the figure
in the beginning of this section for the mapping between the
GUI port number and the physical port on the chassis.
Defines a description of the port.
By default, the value is "User Port #<row index>".
Note: Each row must be configured with a unique name.
(Read-only) Displays the mode of the port.
[0] Disable
[1] Enable (default)