Snmp-Based Management; Enabling Snmp; Configuring Snmp Community Strings - AudioCodes Mediant 800B User Manual

Gateway & e-sbc
Hide thumbs Also See for Mediant 800B:
Table of Contents

Advertisement

User's Manual
8

SNMP-Based Management

The device provides an embedded SNMP agent that lets you manage it using AudioCodes
Element Management System (EMS) or a third-party SNMP manager. The SNMP agent
supports standard and proprietary Management Information Base (MIBs). All supported
MIB files are supplied to customers as part of the release. The SNMP agent can send
unsolicited SNMP trap events to the SNMP manager.
Note:
By default, SNMP-based management is enabled.
For more information on the device's SNMP support such as SNMP trap alarms
and events, refer to the SNMP Reference Guide.
For more information on AudioCodes EMS, refer to the EMS User's Manual.
8.1

Enabling SNMP

By default, SNMP is enabled. You can enable SNMP as described in the following
procedure.
To enable SNMP:
1.
Open the SNMP Community Settings page (Setup menu > Administration tab >
SNMP folder > SNMP Community Settings).
2.
Under the Misc. Settings group, from the 'Disable SNMP' drop-down list
(DisableSNMP parameter), select Yes.
3.
Click Apply.
8.2

Configuring SNMP Community Strings

SNMP community strings determine the access privileges (read-only and read-write) of
SNMP clients with the device's SNMP agent. You can configure up to five read-only SNMP
community strings and up to five read-write SNMP community strings. The device's SNMP
agent accepts SNMP Get (read-only) and Set (read-write) requests only if the correct
community string is used in the request.
You can also configure a unique password-like community string used for sending SNMP
traps. The device sends the traps with the community string.
Version 7.2
Figure 8-1: Enabling SNMP
87
8. SNMP-Based Management
Mediant 800B Gateway & E-SBC

Advertisement

Table of Contents
loading

Table of Contents