AudioCodes Mediant 800B User Manual page 67

Gateway & e-sbc
Hide thumbs Also See for Mediant 800B:
Table of Contents

Advertisement

User's Manual
Parameter
General
Index
Username
user
Password
password
User Level
privilege
Status
status
Version 7.2
Table 6-7: Local Users Table Parameter Descriptions
Defines an index number for the new table row.
Note: Each row must be configured with a unique index.
Defines the Web user's username.
The valid value is a string of up to 40 alphanumeric characters,
including the period ".", underscore "_", and hyphen "-" signs.
Defines the Web user's password.
The valid value is a string of 8 to 40 ASCII characters. To ensure strong
passwords, adhere to the following password complexity requirements:
Contain at least eight characters.
Contain at least two letters that are upper case (e.g., A).
Contain at least two letters that are lower case (e.g., a).
Contain at least two numbers (e.g., 4).
Contain at least two symbols (non-alphanumeric characters) (e.g., $,
#, %).
No spaces.
Contain at least four new characters that were not used in the
previous password.
Note: To enforce the password complexity requirements mentioned
above, configure the EnforcePasswordComplexity to 1.
Defines the user's access level.
Monitor = (Default) Read-only user. This user can only view Web
pages and access to security-related pages is denied.
Administrator = Read/write privileges for all pages except security-
related pages including the Local Users table where this user has
read-only privileges.
Security Administrator = Full read/write privileges for all pages.
Master = Read/write privileges for all pages. This user also functions
as a security administrator.
Note:
At least one Security Administrator must exist. You cannot delete
the last remaining Security Administrator.
The first Master user can be added only by a Security Administrator
user.
Additional Master users can be added, edited and deleted only by
Master users.
If only one Master user exists, it can be deleted only by itself.
Master users can add, edit, and delete Security Administrators
(except the last Security Administrator).
Only Security Administrator and Master users can add, edit, and
delete Administrator and Monitor users.
Defines the status of the user.
New = (Default) User is required to change its password on the next
login. When the user logs in to the Web interface, the user is
immediately prompted to change the current password.
Description
67
Mediant 800B Gateway & E-SBC
6. Web-Based Management

Advertisement

Table of Contents
loading