GE 469 Instruction Manual page 219

Motor management relay
Hide thumbs Also See for 469:
Table of Contents

Advertisement

CHAPTER 5: SETTINGS
5.9.4
RTD 11
 RTD #11
469 MOTOR MANAGEMENT RELAY – INSTRUCTION MANUAL
RTDs 7 through 10 default to "Bearing" RTD type. There are individual alarm and trip
configurations for each RTD. This allows one of the RTDs to be turned off if it malfunctions.
The alarm level, high alarm level and the trip level are normally set slightly above the
normal running temperature, but below the bearing temperature rating. Trip voting has
been added for extra reliability in the event of RTD malfunction. If enabled, a second RTD
must also exceed the trip temperature of the RTD being checked before a trip will be
issued. If the RTD is chosen to vote with itself, the voting feature is disabled. Each RTD
name may be changed if desired.

PATH: SETTINGS
S8 RTD TEMPERATURE
[]
RTD #11 APPLICATION:
Other
RTD #11 NAME:
MESSAGE
RTD #11 ALARM:
MESSAGE
Off
ASSIGN ALARM RELAYS:
MESSAGE
Alarm
RTD #11 ALARM
MESSAGE
TEMPERATURE: 80°C
RTD #7 HIGH ALARM:
MESSAGE
Off
HIGH ALARM RELAYS:
MESSAGE
Alarm
RTD #11 HIGH ALARM
MESSAGE
TEMPERATURE: 80°C
RTD #11 ALARM
MESSAGE
EVENTS: Off
RTD #11 TRIP:
MESSAGE
Off
RTD #11 TRIP VOTING:
MESSAGE
RTD #11
ASSIGN TRIP RELAYS:
MESSAGE
Trip
RTD #11 TRIP
MESSAGE
TEMPERATURE: 90°C
RTD 11 defaults to "Other" RTD type. The Other selection allows the RTD to be used to
monitor any temperature that might be required, either for a process or additional
bearings or other. There are individual alarm, high alarm and trip configurations for this

RTD #11
Range: Stator, Bearing, Ambient, Other,
None
Range: 8 alphanumeric characters
Range: Off, Latched, Unlatched
Range: Alarm, Alarm & Auxiliary2,
Alarm & Aux2 & Aux3, Alarm &
Auxiliary3, Auxiliary2, Aux2 &
Aux3, Auxiliary3, None
Range: 1 to 250°C in steps of 1
Range: Off, Latched, Unlatched
Range: Alarm, Alarm & Auxiliary2,
Alarm & Aux2 & Aux3, Alarm &
Auxiliary3, Auxiliary2, Aux2 &
Aux3, Auxiliary3, None
Range: 1 to 250°C in steps of 1
Range: On, Off
Range: Off, Latched, Unlatched
Range: RTD #1 to RTD #12
Range: Trip, Trip & Auxiliary2, Trip &
Aux2 & Aux3, Trip & Auxiliary3
Range: 1 to 250°C in steps of 1
5–75

Advertisement

Table of Contents
loading

Table of Contents