Section 3: Installation & Setup
h.
CONNECT LAMP LEADS
1. Ensure the igniter door is open. From the ballast in the pedestal, route the main black and white
lamp leads through the nearby hole in the underside of the projection head. See Figure 3-9.
2. Route the NEGATIVE (-) BLACK lamp lead through the hole in the lamp cooling compartment
wall. Warning! 1) Ensure the PCB is directed toward the back and remains at least ¾" from the high-
voltage terminal (with braid connection). 2) Route all igniter wires AWAY from 9-pin and 15-pin con-
nectors. 3) Twist both ballast cables twice-per-foot.
3. Connect the POSITIVE (+) WHITE lamp lead to the POSITIVE (+) igniter terminal (3/4"
wrench). This terminal also has a small PCB attached—stack this on top of the lamp lead.
4. Close and lock the igniter door.
IN THE LAMP COOLING COMPARTMENT:
5. With the lamp door removed (refer back to Figure 3-5), turn the small knob and swing open the
lamp cooling compartment door (Figure 3-10).
3-6
:
Figure 3-9 Connect Lamp Leads
Figure 3-10 Accessing Cathode End