c. Hand-tighten set screws in both negative
and positive lamp connectors (Figure 4-
2). Important! Proper electrical con-
tact prevents resistance in the lamp con-
nectors.If you accidentally touch the
quartz body of the lamp with your bare
hands, clean it as described in
4.1 Maintenance and
STEP 9: Check Leads
Ensure that the anode (+) lead between lamp
and igniter is well away from any projector
metal such as the reflector or firewall.
Warning! Leads too close to metal parts
will cause arcing during starting pulse. This
is a SAFETY HAZARD, and the lamp may
not ignite.
STEP 10: Close Cooling Compartment and Lamp Door
The projector will not operate unless the louvered door is locked shut.
STEP 11: Turn Breakers to ON
At the projector's breaker panel, turn all breakers to ON.
STEP 12: Set Proper Lamp Type (Power)
NOTE: Skip this step if your new lamp is the same size as the old lamp-the Lamp Type will still be correct
in the Install menu.
Important! Requires access to TPC Installer menu.
If your new lamp is larger or smaller than the old lamp, record the new lamp type (2.0, 3.0, 4.5 or 6.0 kW)
in the Touch Panel Controller's Install menu before igniting the new lamp. This setting establishes the
proper range of power available for the installed lamp, ensuring that the new lamp is neither under-pow-
ered nor over-driven. Warning! Do not attempt to ignite the lamp until its type (kW) is correctly set in the
Install menu.
STEP 13: Turn the Lamp ON and Adjust the Lamp Position
Press and hold the lamp button on the TPC Main menu. Using the TPC, adjust the lamp position within the
projector. Refer to Section 3.7 Working with the Lamp in the CP2000-SB User Manual (020-100162-xx).
This ensures maximum performance, with the lamp (bulb) well-centered with the reflector and distanced
correctly from the rest of the illumination system.
STEP 14: Record the Serial Number of the New Lamp
a. In the Advanced: Lamp menu, select New Lamp.
b. In the Lamp History submenu, enter the serial number in the text box.
c. Save to record the number and to reset the lamp timer. The timer will now begin to log time for the