Fabricating External I/O Signal Cable - Toshiba TS2000 Instruction Manual

Robot controller
Hide thumbs Also See for TS2000:
Table of Contents

Advertisement

4.9

Fabricating External I/O Signal Cable

When fabricating an external I/O signal cable, observe the following matters.
a.
Connectors CN5 and CN6 for the TS2000/TS2100 robot controller should be
either the connectors attached to the controller or equivalent connectors.
For CN12, prepare the following connector.
The equivalent of other makers (D-SUB connectors) can also be used.
Connector name
CN5
CN6
CN12
b.
Select the cables which meet the following specifications.
Core wires
Cable outer diameter
Shield
Cable length
NEVER use cables which do not conform to the specifications. Otherwise,
short-circuit or cable melting due to overheated cable core may be caused.
Additionally, the robot may work improperly due to noise.
c.
The CN5, CN6 and CN12 connectors are of a solder cup type which joints
cables by soldering. For how to joint cables to connectors and how to shield
cables, see Section 12.
Type of connector
XM2D–3701 (socket type connector)
XM2S–3711 (connector cover)
XM2A–3701 (pin type connector)
XM2S–3711 (connector cover)
XM2A–2501 (pin type connector)
XM2S–2511 (connector cover)
:
0.18 mm
:
Max. 10.5 mm (CN5, CN6), 9 mm (CN12)
:
Batch shield
:
30 m or less
– 81 –
INTERFACE MANUAL
2
2
~ 0.32 mm
twisted wires
Maker
OMRON
OMRON
OMRON
STE 71367