8.1.2

Connecting Extension Output Signal Cable

To connect the extension output signal cable, use the connector attached to the
TR48DIOCN module [XM2A–2501 (plug type connector), XM2S–2511 (connector
cover)]. Connect the outputs of the TR48DIOCN (DO_101 ~ 120 (station 0) and
DO_133 ~ 152 (station 1) to connector OUTPUT provided on the module surface.
TR48DIOCN
Sink type ("-" common)
DO_10
~
DO_133 DO_152
~
P24G
Note 1:
All of DO_101 ~ 120, DO_133 ~
152 in the figure above are the
transistor outputs.
FG
The specifications of the extension output signal are the same as those of the
digital output signal (i.e., sink type) which are described in Para. 4.7.
OUTPUT
1
14
2
15
3
16
4
17
DO_120
5
18
6
19
7
20
8
21
9
22
10
23
11
24
12
25
13
Case
User side
Station 0/Station 1
DO_101/DO_133
DO_102/DO_134
DO_103/DO_135
DO_104/DO_136
DO_105/DO_137
DO_106/DO_138
DO_107/DO_139
DO_108/DO_140
P24V
P24V
DO_109/DO_141
DO_110/DO_142
DO_111/DO_143
DO_112/DO_144
DO_113/DO_145
DO_114/DO_146
DO_115/DO_147
DO_116/DO_148
P24V
P24V
DO_117/DO_149
DO_118/DO_150
DO_119/DO_151
DO_120/DO_152
P24V
– 101 –
INTERFACE MANUAL
(Station 0/Station 1):
Signal name of DOUT command
(101/133)
(102/134)
(103/135)
(104/136)
(105/137)
(106/138)
(107/139)
(108/140)
(109/141)
(110/142)
(111/143)
(112/144)
(113/145)
(114/146)
(115/147)
(116/148)
(117/149)
(118/150)
(119/151)
(120/152)
STE 71367