Standards and certifications • Emission requirements
Test carried out according to
EN 55011 / EN 55022
1)
Power mains connections
150 kHz - 500 kHz
Power mains connections
500 kHz - 30 MHz
Other connections
150 kHz - 500 kHz
Other connections
500 kHz - 30 MHz
Table 192: Test requirements - Network-related emissions for industrial areas (Forts.)
1) AC network connections only with EN 61131-2

3.2 Emissions, electromagnetic emissions

Test carried out according to
EN 55011 / EN 55022
30 MHz - 230 MHz
measured at a distance of 10 m
230 MHz - 1 GHz
measured at a distance of 10 m
Test carried out according to
EN 55011 / EN 55022
30 MHz - 230 MHz
measured at a distance of 10 m
230 MHz - 1 GHz
measured at a distance of 10 m
Test carried out
30 MHz - 88 MHz
measured at a distance of 10 m
88 MHz - 216 MHz
measured at a distance of 10 m
216 MHz - 960 MHz
measured at a distance of 10 m
>960 MHz
measured at a distance of 10 m
Table 193: Test requirements - Electromagnetic emissions for industrial areas
488
Limits according to
EN 61131-2
79 dB (µV)
Quasi-peak value
66 dB (µV)
Average
73 dB (µV)
Quasi-peak value
60 dB (µV)
Average
-
-
Limits according to
EN 61000-6-4
< 40 dB (µV/m)
Quasi-peak value
< 47 dB (µV/m)
Quasi-peak value
Limits according to
EN 61131-2
< 40 dB (µV/m)
Quasi-peak value
< 47 dB (µV/m)
Quasi-peak value
Limits according to 47 CFR Part
15 Subpart B class A
< 90 dB (µV/m)
Quasi-peak value
< 150 dB (µV/m)
Quasi-peak value
< 210 dB (µV/m)
Quasi-peak value
< 300 dB (µV/m)
Quasi-peak value
Limits according to
47 CFR Part 15 Subpart B class
A
79 dB (µV)
Quasi-peak value
66 dB (µV)
Average
73 dB (µV)
Quasi-peak value
60 dB (µV)
Average
Limits according to
EN 55011 class A
< 40 dB (µV/m)
Quasi-peak value
< 47 dB (µV/m)
Quasi-peak value
Power Panel 300/400 User's Manual V 2.10
Limits according to
EN 55022 class A
< 40 dB (µV/m)
Quasi-peak value
< 47 dB (µV/m)
Quasi-peak value