4.17.4 Cutout installation
The cutout hole is to be made according to the following dimensions for cutout installation. The
device must be mounted using the retaining clips included in delivery.
245
238.5
11.7
4.17.5 Contents of delivery
The following components are included in the delivery of the Power Panel device:
Amount
1
6
1
Power Panel 300/400 User's Manual V 2.10
Technical data • Power Panel 400 with Automation Runtime
Outer contour (Power Panel)
Cutout dimensions 199 ±0.5 mm x 226.8 ±0.5 mm
0
Figure 179: Cutout installation - 4PP451.0571-85
Component
Power Panel PP451 5.7" QVGA, 1 aPCI, keys
Retaining clips included
Lithium battery 3 V / 950 mAh included
Table 98: Contents of delivery - 4PP451.0571-85
Cutout
for
4PP351.0571-01
4PP351.0571-35
4PP451.0571-45
4PP451.0571-65
4PP451.0571-75
4PP451.0571-85
4PP451.0571-B5
265