Power Panel 300 With Automation Runtime; Device Interfaces; Supply Voltage - B&R Industries Power Panel 300 User Manual

Hide thumbs Also See for Power Panel 300:
Table of Contents

Advertisement

Technical data • Power Panel 300 with Automation Runtime

3. Power Panel 300 with Automation Runtime

3.1 Device interfaces

The following section provides a description of all interfaces and plugs possible with a
Power Panel 300 device with Automation Runtime.

3.1.1 Supply voltage

Input voltage: 18 - 30 VDC
The 3-pin socket required for the supply voltage connection is not included in delivery. This can
be ordered from B&R using the model number 0TB103.9 (screw clamps) or 0TB103.91 (cage
clamps).
The pin assignments can be found either in the following table or printed on the Power Panel
plate. The supply voltage is internally protected so that the device cannot be damaged if there is
an overload (fuse replacement necessary) or if the voltage supply is connected incorrectly
(reverse polarity protection - fuse replacement not necessary).
Protected against reverse polarity
Pin
1
2
3
Accessories
0TB103.9
Plug 24 V 5.08 3p screw clamps
0TB103.91
Plug 24 V 5.08 3p cage clamps
Ground
Warning!
The pin's connection to the functional ground (pin 2, e.g. switching cabinet) should
be as short as possible. We recommend using the largest possible conductor cross
section on the supply plug.
102
Description
-
Functional ground
+
Figure 50: Supply voltage connection
Supply voltage
Power Panel 300/400 User's Manual V 2.10
3
2
1

Hide quick links: