Programming
6.3.10 8-** Comm. and Options
Par. No. #
Parameter description
8-0* General Settings
8-01
Control site
8-02
Control word source
8-03
Control word timeout time
8-04
Control word timeout function
8-05
End-of-timeout function
8-06
Reset control word timeout
8-07
Diagnosis trigger
6
6
8-08
Readout filtering
8-1* Ctrl. Word Settings
8-10
Control word profile
8-13
Configurable status word STW
8-14
Configurable control word CTW
8-3* FC Port Settings
8-30
Protocol
8-31
Address
8-32
FC port baud rate
8-33
Parity/stop bits
8-34
Estimated cycle time
8-35
Minimum response delay
8-36
Max response delay
8-37
Max inter-char delay
8-4* FC MC protocol set
8-40
Telegram selection
8-41
Parameters for signals
8-42
PCD write configuration
8-43
PCD read configuration
8-5* Digital/Bus
8-50
Coasting select
8-51
Quick stop select
8-52
DC brake select
8-53
Start select
8-54
Reversing select
8-55
Set-up select
8-56
Preset reference select
8-57
Profidrive OFF2 select
8-58
Profidrive OFF3 select
8-8* FC Port Diagnostics
8-80
Bus message count
8-81
Bus error count
8-82
Slave messages rcvd
8-83
Slave error count
8-9* Bus Jog
8-90
Bus jog 1 speed
8-91
Bus jog 2 speed
86
Operating Instructions
Default value
[0] Digital and
ctrl.word
null
1.0 s
null
[1] Resume set-up
[0] Do not reset
[0] Disable
null
[0] FC profile
null
[1] Profile default
[0] FC
1 N/A
null
[0] Even Parity, 1 Stop
Bit
0 ms
10 ms
App.Dependent
App.Dependent
[1] Standard telegram
1
0
App.Dependent
App.Dependent
[3] Logic OR
[3] Logic OR
[3] Logic OR
[3] Logic OR
[3] Logic OR
[3] Logic OR
[3] Logic OR
[3] Logic OR
[3] Logic OR
0 N/A
0 N/A
0 N/A
0 N/A
100 RPM
App.Dependent
Danfoss A/S © Rev. 2014-07-29 All rights reserved.
4-set-up
FC 302
Change
only
during
operation
All set-ups
TRUE
All set-ups
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
All set-ups
TRUE
2 set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
2 set-ups
TRUE
All set-ups
TRUE
1 set-up
TRUE
1 set-up
TRUE
2 set-ups
TRUE
All set-ups
FALSE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
Conver-
Type
sion
index
-
Uint8
-
Uint8
-1
Uint32
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
0
Uint8
-
Uint8
-
Uint8
-3
Uint32
-3
Uint16
-3
Uint16
-5
Uint16
-
Uint8
-
Uint16
-
Uint16
-
Uint16
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
0
Uint32
0
Uint32
0
Uint32
0
Uint32
67
Uint16
67
Uint16
MG37A202