Programming
6.3.5 3-** Reference/Ramps
Par. No. # Parameter description
3-0* Reference Limits
3-00
Reference range
3-01
Reference/feedback unit
3-02
Minimum reference
3-03
Maximum reference
3-04
Reference function
3-1* References
3-10
Preset reference
3-11
Jog speed [Hz]
6
6
3-12
Catch up/slow down value
3-13
Reference site
3-14
Preset relative reference
3-15
Reference resource 1
3-16
Reference resource 2
3-17
Reference resource 3
3-18
Relative scaling reference resource
3-19
Jog speed [RPM]
3-4* Ramp 1
3-40
Ramp 1 type
3-41
Ramp 1 ramp up time
3-42
Ramp 1 ramp down time
3-45
Ramp 1 S-ramp ratio at accel. start
3-46
Ramp 1 S-ramp tatio at accel. end
3-47
Ramp 1 S-ramp ratio at decel. start
3-48
Ramp 1 S-ramp ratio at decel. end
3-5* Ramp 2
3-50
Ramp 2 type
3-51
Ramp 2 ramp up time
3-52
Ramp 2 Ramp down time
3-55
Ramp 2 S-ramp ratio at accel. start
3-56
Ramp 2 S-ramp ratio at accel. end
3-57
Ramp 2 S-ramp ratio at decel. start
3-58
Ramp 2 S-ramp ratio at decel. end
3-6* Ramp 3
3-60
Ramp 3 type
3-61
Ramp 3 ramp up time
3-62
Ramp 3 ramp down time
3-65
Ramp 3 S-ramp ratio at accel. start
3-66
Ramp 3 S-ramp ratio at accel. end
3-67
Ramp 3 S-ramp ratio at decel. start
3-68
Ramp 3 S-ramp ratio at decel. end
3-7* Ramp 4
3-70
Ramp 4 type
3-71
Ramp 4 ramp up time
3-72
Ramp 4 ramp down time
3-75
Ramp 4 S-ramp ratio at accel. start
3-76
Ramp 4 S-ramp ratio at accel. end
3-77
Ramp 4 S-ramp ratio at decel. start
3-78
Ramp 4 S-ramp ratio at decel. end
78
Operating Instructions
Default value
null
null
App.Dependent
App.Dependent
[0] Sum
0.00 %
App.Dependent
0.00 %
[0] Linked to hand/auto
0.00 %
null
null
null
[0] No function
App.Dependent
[0] Linear
App.Dependent
App.Dependent
50 %
50 %
50 %
50 %
[0] Linear
App.Dependent
App.Dependent
50 %
50 %
50 %
50 %
[0] Linear
App.Dependent
App.Dependent
50 %
50 %
50 %
50 %
[0] Linear
App.Dependent
App.Dependent
50 %
50 %
50 %
50 %
Danfoss A/S © Rev. 2014-07-29 All rights reserved.
4-set-up
FC 302
Change
only
during
operation
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
Conver-
Type
sion
index
-
Uint8
-
Uint8
-3
Int32
-3
Int32
-
Uint8
-2
Int16
-1
Uint16
-2
Int16
-
Uint8
-2
Int32
-
Uint8
-
Uint8
-
Uint8
-
Uint8
67
Uint16
-
Uint8
-2
Uint32
-2
Uint32
0
Uint8
0
Uint8
0
Uint8
0
Uint8
-
Uint8
-2
Uint32
-2
Uint32
0
Uint8
0
Uint8
0
Uint8
0
Uint8
-
Uint8
-2
Uint32
-2
Uint32
0
Uint8
0
Uint8
0
Uint8
0
Uint8
-
Uint8
-2
Uint32
-2
Uint32
0
Uint8
0
Uint8
0
Uint8
0
Uint8
MG37A202