Programming
Par. No. #
Parameter description
33-5* I/O Configuration
33-50
Terminal X57/1 digital input
33-51
Terminal X57/2 digital input
33-52
Terminal X57/3 digital input
33-53
Terminal X57/4 digital input
33-54
Terminal X57/5 digital input
33-55
Terminal X57/6 digital input
33-56
Terminal X57/7 digital input
33-57
Terminal X57/8 digital input
33-58
Terminal X57/9 digital input
33-59
Terminal X57/10 digital input
6
6
Terminal X59/1 and X59/2
33-60
mode
33-61
Terminal X59/1 digital input
33-62
Terminal X59/2 digital input
33-63
Terminal X59/1 digital output
33-64
Terminal X59/2 digital output
33-65
Terminal X59/3 digital output
33-66
Terminal X59/4 digital output
33-67
Terminal X59/5 digital output
33-68
Terminal X59/6 digital output
33-69
Terminal X59/7 digital output
33-70
Terminal X59/8 digital output
33-8* Global Parameters
33-80
Activated program number
33-81
Power-up state
33-82
Drive status monitoring
33-83
Behaviour after error
33-84
Behaviour after esc.
MCO supplied by external 24 V
33-85
DC
33-86
Terminal at alarm
33-87
Terminal state at alarm
33-88
Status word at alarm
33-9* MCO Port Settings
33-90
X62 MCO CAN node ID
33-91
X62 MCO CAN baud rate
X60 MCO RS485 serial
33-94
termination
X60 MCO RS485 serial baud
33-95
rate
104
Operating Instructions
Default value
4-set-up
[0] No function
2 set-ups
[0] No function
2 set-ups
[0] No function
2 set-ups
[0] No function
2 set-ups
[0] No function
2 set-ups
[0] No function
2 set-ups
[0] No function
2 set-ups
[0] No function
2 set-ups
[0] No function
2 set-ups
[0] No function
2 set-ups
[1] Output
2 set-ups
[0] No function
2 set-ups
[0] No function
2 set-ups
[0] No function
2 set-ups
[0] No function
2 set-ups
[0] No function
2 set-ups
[0] No function
2 set-ups
[0] No function
2 set-ups
[0] No function
2 set-ups
[0] No function
2 set-ups
[0] No function
2 set-ups
-1 N/A
2 set-ups
[1] Motor on
2 set-ups
[1] On
2 set-ups
[0] Coast
2 set-ups
[0] Controlled stop
2 set-ups
[0] No
2 set-ups
[0] Relay 1
2 set-ups
[0] Do nothing
2 set-ups
0 N/A
2 set-ups
127 N/A
2 set-ups
[20] 125 Kbps
2 set-ups
[0] Off
2 set-ups
[2] 9600 Baud
2 set-ups
Danfoss A/S © Rev. 2014-07-29 All rights reserved.
FC 302
Change
Conver-
only
during
sion index
operation
TRUE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
-
FALSE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
0
TRUE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
0
TRUE
0
TRUE
-
TRUE
-
TRUE
-
Type
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Int8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint16
Uint8
Uint8
Uint8
Uint8
MG37A202