Programming
6.3.7 5-** Digital In/Out
Par. No. # Parameter description
5-0* Digital I/O mode
5-00
Digital I/O mode
5-01
Terminal 27 mode
5-02
Terminal 29 mode
5-1* Digital Inputs
5-10
Terminal 18 digital input
5-11
Terminal 19 digital input
5-12
Terminal 27 digital input
5-13
Terminal 29 digital input
5-14
Terminal 32 digital input
5-15
Terminal 33 digital input
5-16
Terminal X30/2 digital input
5-17
Terminal X30/3 digital input
5-18
Terminal X30/4 digital input
5-19
Terminal 37 safe stop
5-20
Terminal X46/1 digital input
5-21
Terminal X46/3 digital input
5-22
Terminal X46/5 digital input
5-23
Terminal X46/7 digital input
5-24
Terminal X46/9 digital input
5-25
Terminal X46/11 digital input
5-26
Terminal X46/13 digital input
5-3* Digital Outputs
5-30
Terminal 27 digital output
5-31
Terminal 29 digital output
5-32
Term X30/6 digi out (MCB 101)
5-33
Term X30/7 digi out (MCB 101)
5-4* Relays
5-40
Function relay
5-41
On delay, relay
5-42
Off delay, relay
5-5* Pulse Input
5-50
Term. 29 low frequency
5-51
Term. 29 high frequency
5-52
Term. 29 low ref./feedb. value
5-53
Term. 29 high ref./feedb. value
5-54
Pulse filter time constant #29
5-55
Term. 33 low frequency
5-56
Term. 33 high frequency
5-57
Term. 33 low ref./feedb. value
5-58
Term. 33 high ref./feedb. value
5-59
Pulse filter time constant #33
MG37A202
Operating Instructions
Default value
[0] PNP
All set-ups
[0] Input
All set-ups
[0] Input
All set-ups
null
All set-ups
null
All set-ups
null
All set-ups
null
All set-ups
null
All set-ups
null
All set-ups
null
All set-ups
null
All set-ups
null
All set-ups
[1] Safe Stop Alarm
[0] No operation
All set-ups
[0] No operation
All set-ups
[0] No operation
All set-ups
[0] No operation
All set-ups
[0] No operation
All set-ups
[0] No operation
All set-ups
[0] No operation
All set-ups
null
All set-ups
null
All set-ups
null
All set-ups
null
All set-ups
null
All set-ups
0.01 s
All set-ups
0.01 s
All set-ups
100 Hz
All set-ups
100 Hz
All set-ups
0.000 ReferenceFeed-
backUnit
All set-ups
App.Dependent
All set-ups
100 ms
All set-ups
100 Hz
All set-ups
100 Hz
All set-ups
0.000 ReferenceFeed-
backUnit
All set-ups
App.Dependent
All set-ups
100 ms
All set-ups
Danfoss A/S © Rev. 2014-07-29 All rights reserved.
4-set-up
FC 302
Change
only
during
operation
FALSE
TRUE
x
TRUE
TRUE
TRUE
TRUE
x
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
1 set-up
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
x
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
x
TRUE
x
TRUE
x
TRUE
x
TRUE
x
FALSE
TRUE
TRUE
TRUE
TRUE
FALSE
Conver-
Type
sion
index
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
6
6
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-2
Uint16
-2
Uint16
0
Uint32
0
Uint32
-3
Int32
-3
Int32
-3
Uint16
0
Uint32
0
Uint32
-3
Int32
-3
Int32
-3
Uint16
81