Refresh Device Read (In 1-Bit Units) - Mitsubishi Electric MELSEC-Q/L Programming Manual

Hide thumbs Also See for MELSEC-Q/L:
Table of Contents

Advertisement

Refresh device read (in 1-bit units)

S(P).REFDVRDB
High
Basic
Process
performance
• QnUD(H)CPU, QnUDE(H)CPU: the serial number (first five digits) is "14072" or later
• QnUDVCPU: the serial number (first five digits) is "16043" or later.
• Built-in Ethernet port LCPU: Supported
• Q00UJCPU, Q00UCPU, Q01UCPU, Q02UCPU, L02SCPU, and L02SCPU-P cannot be used.
S.REFDVRDB
SP.REFDVRDB
n1:
Start I/O number (0H to FEH) (BIN 16-bit)
(S1): Start number of the device stored control data (device name)
(D1): Start number of the device stored read data from the refresh device assigned the device specified in (S1)+0 and (S1)+1 (device name)
n2:
Number of read points (1 to 2147483647) (BIN 32-bit)
(D2): Start number of the bit device which turns on for 1 scan by the instruction completion. (D1)+1 also turns on at the error completion (bit).
Setting
Internal device
data
Bit
n1
(S1)
*2
(D1)
n2
*2
(D2)
*1 The first 3 digits of the hexadecimal 4 digits which represent the start I/O number.
*2 Local devices and the devices designated for individual programs cannot be used.
Processing details
• The contents of the data stored in the area starting from (S1) are as indicated below.
Device
Item
(S1)+0
Station number
(S1)+1
Type
(S1)+2
Offset
(S1)+3
• Instruction execution possibility of an execution type for each program.
• Enabled: Initial program and scan execution type program
• Disabled: Fixed scan execution type program and interrupt program
• To read data from a refresh device, the data reflection to the station number specified by the instruction is executed at the
timing for the auto refresh.
8 INSTRUCTIONS FOR DATA LINK
838
8.3 Refresh Device Write/Read Instructions
Ver.
Ver.
Redundant
Universal
LCPU
Command
Command
*1
of the master station controlling the station assigned the refresh device which reads data
R, ZR
Word
Setting contents
Station number for the station assigned the refresh device which reads data.
When the link special relay (SB) is specified as type of (S1)+1, the setting is disabled.
Type of the refresh device which reads data
• 1: Remote input (RX)
• 2: Remote output (RY)
• 3: Link special relay (SB)
Offset from the head of the refresh device assigned the device specified in (S1)+0 and (S1)+1
S.REFDVRDB
SP.REFDVRDB
J\
U\G
Bit
Word
n1
S1
D1
n2
D2
n2
n1
S1
D1
D2
Zn
Constant
K, H
Setting range
1 to 120
1 to 3
0 to 2147483647
Others