Instruction
$MOV
$MOVP
CML
CMLP
DCML
DCMLP
BMOV (S) (D) n
BMOVP (S) (D) n
FMOV (S) (D) n
FMOVP (S) (D) n
XCH
XCHP
DXCH
DXCHP
BXCH (D1) (D2) n
BXCHP (D1) (D2) n
SWAP
SWAPP
CJ
SCJ
JMP
GOEND
DI
EI
IMASK
IRET
RFS
RFSP
■Application instructions
The processing time when the instruction is not executed is calculated as follows:
• Q00JCPU: 0.20  (No. of steps for each instruction + 1) s
• Q00CPU: 0.16  (No. of steps for each instruction + 1) s
• Q01CPU: 0.10  (No. of steps for each instruction + 1) s
Instruction
WAND (S) (D)
WANDP (S) (D)
WAND (S1) (S2) (D)
WANDP (S1) (S2) (D)
DAND (S) (D)
DANDP (S) (D)
DAND (S1) (S2) (D)
DANDP (S1) (S2) (D)
BKAND (S1) (S2) (D) n
BKANDP (S1) (S2) (D) n
WOR (S) (D)
WORP (S) (D)
WOR (S1) (S2) (D)
WORP (S1) (S2) (D)
DOR (S) (D)
DORP (S) (D)
APPENDICES
890
Appendix 1 Operation Processing Time
Condition (device)
0 characters
32 characters
n=1
n=96
n=1
n=96
n=1
n=96
X
n=1
n=96
Y
n=1
n=96
Condition (device)
When executed
When executed
When executed
When executed
n=1
n=96
When executed
When executed
When executed
Processing time (s)
Q00JCPU
Q00CPU
46
38
98
80
0.70
0.56
0.90
0.72
27
21
72
62
23
19
48
41
7.6
6.3
9.5
8.0
62
51
165
140
17
14
10
8.5
10
8.5
11
8.5
3.3
2.9
13
12
14
11
41
34
205
170
55
46
79
64
54
45
73
61
Processing time (s)
Q00JCPU
Q00CPU
1.0
0.80
1.2
0.96
1.3
1.04
1.5
1.2
110
87
185
155
1.0
0.80
1.2
0.96
1.3
1.04
Q01CPU
35
73
0.35
0.45
20
53
17
36
5.7
7.1
48
125
13
8.1
8.1
8.1
2.8
11
11
35
155
43
59
41
56
Q01CPU
0.50
0.60
0.65
0.75
79
140
0.50
0.60
0.65