Operation error
• In any of the following cases, an operation error occurs, the error flag (SM0) turns ON, and an error code is stored into SD0.
Error
Error details
code
2410
The device data storage file is not set at "PLC file" of PLC parameter.
4100
The address specified in n1 is out of the standard ROM range.
The address of n2, specified in n1, is out of the standard ROM range.
The value specified in n2 is 0 or a negative value.
4101
The range of n2 exceeds that of the device specified in (D).
Program example
• The program which reads the ten points of data from D100 to the device data storage file in the standard ROM when M0
turns ON.
[Ladder Mode]
7 APPLICATION INSTRUCTIONS
804
7.19 Other Instructions
Q00J/
QnH
Q00/
Q01
[List Mode]
Step
Instruction
QnPH
QnPRH
QnU
Device
LCPU