Mitsubishi Electric MELSEC-Q/L Programming Manual page 760

Hide thumbs Also See for MELSEC-Q/L:
Table of Contents

Advertisement

Operation error
• In any of the following cases, an operation error occurs, the error flag (SM0) turns ON, and an error code is stored into SD0.
Error
Error details
code
4101
The specified device number (serial byte number) exceeds the available
range.
Program example
• The following program reads the lower 8 bits of ZR16000 and the upper 8 bits of ZR16003, and stores them at D100 and
D101 when X0 is ON.
[Ladder Mode]
[Operation]
Serial byte No. 32000
(Lower 8 bits of ZR16000)
Serial byte No. 32007
(Upper 8 bits of ZR16003)
7 APPLICATION INSTRUCTIONS
758
7.19 Other Instructions
b15
b8 b7
b0
ZR16000
8F
25
H
H
ZR16001
42
32
H
H
ZR16002
12
34
H
H
ZR16003
93
00
H
H
Q00J/
QnH
Q00/
Q01
[List Mode]
Step
Instruction
b15
b8 b7
00
25
D100
H
H
D101
00
93
H
H
QnPH
QnPRH
QnU
Device
b0
LCPU

Advertisement

Table of Contents
loading

Table of Contents