Batch reset of bit devices

BKRST(P)
High
Basic
Process
performance
BKRST
BKRSTP
(D): Head number of the devices to be reset (bits)
n:
Number of the devices to be reset (BIN 16 bits)
Setting
Internal device
data
Bit
(D)
n
Processing details
• Resets bit device n-points from the bit device designated by (D).
Device
Annunciator (F)
Timer (T)
Counter (C)
Bit devices other than the
above
• If the designated device is OFF, the device status will not change.
Operation error
• In any of the following cases, an operation error occurs, the error flag (SM0) turns ON, and an error code is stored into SD0.
Error
Error details
code
4101
The points specified in n exceed those of the corresponding device specified
in (D).
7 APPLICATION INSTRUCTIONS
416
7.4 Bit Processing Instructions
Redundant Universal
LCPU
Command
Command
R, ZR
Word
Status
• Turns device n-points from annunciator (F) number designated by (D) OFF.
• Deletes annunciator number turned OFF from SD64 to SD79 and compresses remaining data forward.
• Stores number of annunciators stored from SD64 to SD79 at SD63.
• Sets the current value n-points from timer (T) or counter c designated by (C) to 0, and turns coil contact OFF.
• Turns OFF coil or contact n-points from the device designated by (D).
J\
U\G
Bit
Word
Q00J/
Q00/
Q01
n
D
BKRST
n
D
BKRSTP
Zn