List Of Usage Methods By Purpose - Omron CJ1W-DRM21 Operation Manual

Machine automation controller cj-series, nj-series cpu unit
Hide thumbs Also See for CJ1W-DRM21:
Table of Contents

Advertisement

1 Features and System Configuration
1-5

List of Usage Methods by Purpose

Situation
Design
Allocating any
words for
remote I/O
Using the Unit as a slave
Performing message communi-
cations between controllers to
which DeviceNet Units are
mounted
Mounting multiple DeviceNet
Units using master communica-
tions to a single controller
Mounting multiple DeviceNet
Units using slave communica-
tions to a single controller
Connecting multiple controllers
(master communications) in a
network
Connecting a single Master con-
troller and multiple Slave control-
lers in a network
Sending DeviceNet explicit mes-
sages
Setting the node address for a
DeviceNet Unit
Setting the baud rate for the
DeviceNet Unit
Stopping remote I/O communi-
cations for communications
errors
Storing OUT data in slave I/O
memory for communications
errors
1-22
Not in order of
Set with the use of the CX-Integrator.
node
Note Allocations with the use of CX-Integrator:
addresses
Any node address order and two blocks from
OUT 1, IN 1, OUT 2 and IN 2. Allocation is
much easier with the use of a wizard.
In order of
Set with the use of the device variables for CJ-
node
series Unit.
addresses
(Master user-set Allocations Setup Table and Allo-
cation Size Setup Table)
Note Allocations with the use of device variables
for CJ-series Unit: Fixed node address order
and one block from OUT 1 and IN 1.
Set with the use of the device variables for CJ-
series Unit.
Execute communications instructions from the
user program.
3 Units max. with fixed allocations
16 Units max. with user-set allocations
3 Units max. with fixed allocations
16 Units max. with user-set allocations
Supported by user-set allocations with the use of
device variables for CJ-series Unit or user-set allo-
cations with the use of the CX-Integrator.
Set multiple Controller to Slave mode from the
device variables for CJ-series Unit or the CX-Inte-
grator.
Note Up to 64 Units may be on a network. (Exam-
ple: 1 Master Controller and 63 Slave Con-
trollers)
Set the command code to 2801.
Set the rotary switches on the front of the
DeviceNet Unit.
Set the DIP switch on the front of the DeviceNet
Unit.
Set the DIP switch on the front of the DeviceNet
Unit.
Set the DIP switch on the front of the DeviceNet
Unit.
CJ-series DeviceNet Units Operation Manual for NJ-series CPU Unit(W497)
Action
Section
4-4-1 Settings
through CX-
Integrator
4-4-2 Settings
through Device
Variables for
CJ-series Unit
(Master User-
set Allocations
Setup Table)
5-1 Slave
Remote I/O
Communica-
tions
Section 6 Mes-
sage Commu-
nications
4-1 Master
Remote I/O
Communica-
tions
5-1 Slave
Remote I/O
Communica-
tions
5-1 Slave
Remote I/O
Communica-
tions
5-1 Slave
Remote I/O
Communica-
tions
6-2 Sending
Explicit Mes-
sages
Node Address
Switches on
page 2-6
DIP Switch on
page 2-6
DIP Switch on
page 2-6
DIP Switch on
page 2-6

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents