3 Data Exchange with the CPU Unit
3-2-6

Unit Status 2

The following device variables for CJ-series Unit is used to reference all information of Unit Status 2.
Name of device variable for
CJ-series Unit
*_Unit2Sta
The following device variables for CJ-series Unit are used to reference individual information.
Name of device variable for
CJ-series Unit
*_OnlineSta
3-30
Type
R/W
Area
WORD
R
Unit Status
2
Type
R/W
Area
BOOL
R
Online Sta-
tus
CJ-series DeviceNet Units Operation Manual for NJ-series CPU Unit(W497)
Function
Bit 00: Online Status
Bit 01: Remote I/O Communications Sta-
tus
Bit 02: Reserved by system
Bit 03: Master Function Enabled Status
Bit 04: Scan List Disabled Status
Bit 05: Reserved by system
Bit 06: Automatic Slave Connection Status
Bit 07: Slave Function Enabled Status
Bit 08: File Read/Write Error
Bit 09: Reserved by system
Bit 10: Reserved by system
Bit 11: Reserved by system
Bit 12: Reserved by system
Bit 13: Reserved by system
Bit 14: Reserved by system
Bit 15: Error History Registered Flag
Default: 16#0000
Function
<Operation specifications>
TRUE:
Indicates that the Unit is online.
Note When the Send Command instruc-
tion (SendCmd) is executed from the
user program, use _Port_isAvailable
(Communications
Port
Flag) in the CPU Unit and this flag
as an AND input condition.
FALSE:
Indicates that the Unit is offline.
A Unit will go offline under the following
conditions:
• Operation is stopped by the hard-
ware/software check at startup.
• An error occurred in the duplicate node
address check (Refer to *_NdAdrDupErr
(Node Address Duplicated Error)).
• A Bus OFF error occurred (Refer to
*_BusoffErr (Bus Off Error)).
Default: FALSE
Enabled