Omron CJ1W-DRM21 Operation Manual page 65

Machine automation controller cj-series, nj-series cpu unit
Hide thumbs Also See for CJ1W-DRM21:
Table of Contents

Advertisement

Situation
Operation
Stopping remote I/O communi-
cations with all Slaves
Using a scan list in remote I/O
communications (fixed alloca-
tions)
Enabling a scan list in remote I/O
communications (user-set allo-
cations by device variables for
CJ-series Unit)
Changing the communications
system configuration
Checking master I/O allocations
status (fixed allocations, user-set
allocations by device variables
for CJ-series Unit, user-set allo-
cations with the CX-Integrator)
Checking to see if all slaves are
registered in the scan list
Checking to see if all slaves are
performing remote I/O communi-
cations properly
Checking to see if there is an
error history in the DeviceNet
Unit
Monitoring the error history in
the DeviceNet Unit
Monitoring status of the
DeviceNet Unit
Checking the current communi-
cations cycle time
Adjusting the communications
cycle time
Saving all parameters, like scan
list data, for masters and slaves
on the network
Replacing a DeviceNet Unit
CJ-series DeviceNet Units Operation Manual for NJ-series CPU Unit(W497)
1 Features and System Configuration
Action
Stop communications with the use of the CX-Inte-
grator or *_Sw1IOCommStopCmd (Remote I/O
Communications Stop Switch).
Change *_Sw1SListEnblCmd (Scan List Enable
Switch) to TRUE.
Set the allocation areas with the use of the device
variables for CJ-series Unit, and change
*_Sw1MstrAlocCmd (Master User-set Allocations
Switch) to TRUE.
Change *_Sw1SListClrCmd (Scan List Clear
Switch) to TRUE, and change
*_Sw1SListEnblCmd (Scan List Enable Switch) to
TRUE after you change the communications sys-
tem.
Monitor the Master Status 2 status codes in
*_Mstr2Sta from Sysmac Studio.
Check *_RegSlavTblSta (Registered Slave Table).
Check *_NormSlavTblSta (Normal Slave Table).
Check the error history (registration yes/no) from
Sysmac Studio.
Execute the device monitor function from the CX-
Integrator (Error History Tab).
Execute the device monitor function from the CX-
Integrator (Status and Unit Status Tabs).
Execute the device monitor function from the CX-
Integrator (Current Communications Cycle Time
Tab).
Execute the device parameter edit function from
the CX-Integrator (Communications Cycle Time
Tab).
Save the network configuration from the CX-Inte-
grator.
1. Insert a SD Memory Card in the CPU Unit and
change the Unit Setup File Backup Switch in
the device variables for CJ-series Unit to
TRUE.
2. Replace the DeviceNet Unit.
3. Change Sw2FileRestoreCmd (Unit Setup File
Restore Switch) to TRUE.
4. Change *_Sw1SListEnblCmd (Scan List
Enable Switch) in the device variables for CJ-
series Unit to TRUE.
5. Make sure the slave is connected, and then
change *_Sw1SListEnblCmd (Scan List Clear
Switch) in the device variables for CJ-series
Unit to TRUE.
Section
3-2-1 Software
Switches 1
3-2-1 Software
Switches 1
3-2-1 Software
1
Switches 1
4-2 Scan List
3-2-8 Master
Status 2
3-2-11 Regis-
tered Slave
Table
3-2-12 Normal
Slave Table
3-2-6 Unit Sta-
tus 2, 9-2 Error
Log Functions
CS/CJ/CP/NSJ
Series CX-Inte-
grator Ver.2.@
OPERATION
MANUAL
(W464)
7-1 SD Mem-
ory Card
Backup Func-
tions, 9-5-3
Replacing
Faulty Units
1-23

Hide quick links:

Advertisement

Table of Contents
loading