Cisco D9824 Installation And Configuration Manual page 335

Advanced multi decryption receiver
Table of Contents

Advertisement

Alarm
Message
Type
DL:NVS Flash
Set
Failure
DL:NVS Flash
Set
Failure
Temperature
Set
Alarm
Temperature
Clear
Alarm
Fan
Set
Fan
Clear
Message
Cause/Remedy
APP/SAT7109/PP
Cause: Possible
C CRC/Write has
hardware or
Failed
software issue.
Remedy: Clear
alarms, reset unit,
and notify Cisco
Services if the
problem persists.
TEB Flash Write
Cause: Possible
hardware or
Failed
software issue.
Remedy: Clear
alarms, reset unit,
and notify Cisco
Services if the
problem persists.
Temperature over
Cause: Room
Alarm threshold
temperature too
high, or air flow is
blocked.
Remedy: Check
openings on front
and rear panels for
blockage. Lower
room temperature
or improve air
flow to device.
Temperature
normal
Fan RPM Alarm
Cause: Hardware
issue.
Remedy: Unit
should be
returned to Cisco
Services as soon as
possible.
Fans Operational
Description
Severity
Failed to read
Major
or write flash
memory
Failed to read
Major
or write flash
memory
Temperature is
Major
above safe
operating
range.
Major
Fan RPM out of
Major
normal
operating
range.
Major
ID
27600
27600
28000
28000
29000
29000