Alarm
Message
Type
FEC USB Flash Set
FEC USB Flash Set
FEC USB Flash Clear
FEC FPGA
Set
Status
320
Message
Cause/Remedy
FEC USB Option
Cause: FEC USB
connector not
not installed
installed.
Remedy: Ensure
that the FEC USB
connector and
FLASH module
are installed.
FEC USB Flash not
Cause: FEC USB
FLASH not
found
installed. This
may occur in
Production if the
USB module is not
inserted before the
first power on the
board.
Remedy: Ensure
that the FEC USB
connector and
FLASH module
are installed.
FEC USB Flash
OK
Failed to find or
Cause: Cannot
load FEC FPGA
find the FEC
FPGA file in the
binary
USB FLASH, or it
failed to open,
read, or load the
file to the FEC
FPGA.
Remedy: Ensure
that the USB
FLASH is
installed,
formatted, and the
image is loaded.
Also, ensure that
the FEC FPGA is
installed and the
CPLD is properly
programmed.
Description
Severity
FEC USB
Major
option not
detected.
FEC USB
Major
FLASH mount
failed.
Major
The FEC FPGA
Major
image is not
found in the
USB FLASH, or
the file cannot
be loaded to
the FEC FPGA
for any reason.
This will occur
in production
until the USB
FLASH is
installed,
formatted, and
the image is
loaded.
ID
92300
92300
92300
92400