Multi-Port Mirrored Single Host-Dual Connection Configuration
1
Set the jumper (JP4) on the Disk I/O card to configure the bus speed mode.
Loosen the two captive fastener screws for the Disk I/O card and pull it from
the enclosure using the fastener screws. Locate the jumper JP4 and position it
for the desired speed setting, (installed on one pin only for 2 Gb mode and
on both pins for 1 Gb mode).
FC-AL Loop Port "D1"
Loop Status LEDs
2 Gb/1 Gb Mode LED
FC-AL Loop Port "D2"
Disk I/O Card Jumper Settings for the NexStor 4921F/4922F/4941F/4942F Enclosures
JUMPER
JP1
JP2
JP3
JP4
* indicates default setting
2
Re-install the Disk I/O card. Repeat step 1 for the second Disk I/O card.
3
Locate the switches on the SES Controller card and set them as indicated in
the illustration on the following page. Refer to "SES Controller Card Switch
Setting Overview" on page 56 for the other available settings.
Install jumpers JP1 and JP2
on both pins for each jumper.
Disk I/O Card
INSTALLED BOTH PINS
RAID Controller Systems Only
RAID Controller Systems Only
Split Bus Mode
JBOD Enclosures Only
1 Gb/sec Bus Speed Mode
Multi-Port Mirrored Single Host-Dual Connection Configuration
Chapter 3 - Setup and Installation
Install jumper JP3 on one
pin only for Single Bus mode.
Install jumper JP4 on
both pins for 1Gb mode,
and on one pin only for
2 Gb mode.
INSTALLED ONE PIN (OFFSET)
* Not Applicable
* Not Applicable
* Single Bus Mode
RAID Enclosures and Daisy
Chain JBOD Enclosures
* 2 Gb/sec Bus Speed Mode
77