NexStor 4900F Series User Manual page 74

Raid storage systems
Table of Contents

Advertisement

Chapter 3 - Setup and Installation
2
3
4
5
60
Stand-Alone Dual Port Single Host Configuration
Disk I/O Card Jumper Settings for the NexStor 4911F/4912F/4931F/4932F Enclosures
JUMPER
JP1
RAID Controller Systems Only
JP2
RAID Controller Systems Only
JP3
Split Bus Mode
JBOD Enclosures Only
JP4
1 Gb/sec Bus Speed Mode
* indicates default setting
Re-install the Disk I/O card. Repeat step 1 for the second Disk I/O card.
Locate the switches on the SES Controller card and set them as indicated in
the illustration below. Refer to "SES Controller Card Switch Setting Overview"
on page 56 for the other available settings.
Switch Settings
A
A
A
S
S
B
D
R
D
D
D
P
P
D
L
M
0
1
2
0
1
R
Y
T
UP (1)
1 2 3 4 5 6 7 8
DOWN (0)
SES Controller Card Switch Settings
Set the Host I/O card switches. Position the switches 1, 2, and 4 to the "Up"
position.
Loosen the two captive fastener screws for a Host I/O card and pull it from
the enclosure using the fastener screws. Set the switches as described in the
illustration on the following page. Refer to the "Host I/O Card" on page 13
for switch setting details.
Re-install the Host I/O card. Repeat step 4 for the second Host I/O card.
INSTALLED BOTH PINS
IDs Assigned to Disk Slots
Slot 1
Slot 4
ID 0
ID 2
Slot 2
Slot 5
ID 3
ID 1
Slot 3
Slot 6
ID 9
ID 8
INSTALLED ONE PIN (OFFSET)
* Not Applicable
* Not Applicable
* Single Bus Mode
RAID Enclosures and Daisy
Chain JBOD Enclosures
* 2 Gb/sec Bus Speed Mode
Slot 7
Slot 10
ID 4
ID 6
Slot 8
Slot 11
ID 7
ID 5
Slot 9
Slot 12
ID 11
ID 10

Advertisement