Kikusui PLZ164W User Manual page 184

Plz-4w series
Hide thumbs Also See for PLZ164W:
Table of Contents

Advertisement

Remote sensing
Voltage that can be
compensated
Protection function
Overvoltage protection (OVP) Turns off the load at 110 % of the rated voltage
Overcurrent protection (OCP)
Overpower protection (OPP)
Overheat protection (OHP)
Undervoltage protection
(UVP)
Reverse connection detection
(REV)
Sequence function
Normal
Operation mode
sequence
Maximum number
of steps
Step execution time
Time resolution
Fast
Operation mode
sequence
Maximum number
of steps
Step execution time
Time resolution
Others
Elapsed time display
Auto load off timer
9-6 Specifications
Model
PLZ164W
Model
PLZ164W
0.03 A – 36.3 A
0.06 A – 72.6 A
Or 110 % of the maximum current of each range
Load off or limit selectable
0.1 W – 181.5 W
0.3 W – 363 W
Or 110 % of the maximum power of each range
Load off or limit selectable
Turns off the load when the heat sink temperature reaches 95C
Turns off the load when detected.
Can be set in the range of 0 V to 150 V or Off.
By diode and fuse. Turns off the load when an alarm occurs.
Model
PLZ164W
Model
PLZ164W
Measures the time from load on to load off. On/Off selectable.
Measures from 1 s up to 999 h 59 min 59 s
Automatically turns off the load after a specified time elapses.
Can be set in the range of 1 s to 999 h 59 min 59 s or off
PLZ334W
PLZ1004W
2 V for a single line
PLZ334W
PLZ1004W
0.2 A – 220 A
1 W – 1 100 W
PLZ334W
PLZ1004W
CC, CR, CV, or CP
256
1 ms – 999 h 59 min
1 ms (1 ms – 1 min)
100 ms (1 min – 1 h)
1 s (1 h – 10 h)
10 s (10 h – 100 h)
1 min (100 h – 999 h 59 min)
CC or CR
1024
25 s – 100 ms
25 s (25 s – 100 s)
100 s (100 s – 100 ms)
PLZ334W
PLZ1004W
PLZ164WA
PLZ664WA
PLZ164WA
PLZ664WA
0.03 A – 36.3 A
0.13 A – 145.2 A
0.1 W – 181.5 W
0.6 W – 726 W
PLZ164WA
PLZ664WA
PLZ164WA
PLZ664WA
PLZ-4W