■ Operating procedure of CR+CV mode
MODE
SET / VSET
LOAD
+ CV
MENU
SW ON
FREQ / DUTY
Th/TL
SWITCHING
Fig. 5-6
Keys used in CR+CV mode
1.
Check the operation mode.
Check that CR is indicated on the display.
2.
Select the operation mode.
Press the +CV (SHIFT+MODE) key.
The mode switches to CR+CV.
Check that CR+CV is indicated on the display.
3.
Select the current range and voltage range.
Press the RANGE key to select the current range.
Press the VRANGE (SHIFT+RANGE) key to select the voltage range.
4.
Set the conductance and voltage.
Check that the display is in the basic setting entry condition (the characters
"SET" is highlighted).
While viewing the display, turn the rotary knob.
To switch between conductance and voltage settings, press the SET/VSET key.
5.
Turn on the load.
Press the LOAD key.
The LOAD LED illuminates, and the current flows.
The display shows the measured values (voltage, current, and wattage)
at the load input terminal.
6.
Change the conductance setting.
Turn the rotary knob to change the conductance setting.
The conductance cannot be set greater than the maximum value of the selected
range.
7.
Turn off the load.
Press the LOAD key.
The LOAD LED turns off, and the current is cut off.
LOAD
RANGE
SLEW RATE
OPP / OCP
RECALL
VRANGE
SHORT
UVP
STORE
LEVEL
A
B
C
EDIT
RUN / STOP
PAUSE
I
PRESET SEQ
LOCK
ENTER
ABC
SHIFT
Basic Operation 5-15

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Plz334wPlz1004wPlz164waPlz664wa

Table of Contents