Kikusui PLZ164W User Manual page 128

Plz-4w series
Hide thumbs Also See for PLZ164W:
Table of Contents

Advertisement

Pin
Signal name
No.
1
EXT R/V CONT
2
IMON
3
A COM
4
SUM I MON
5
PRL IN+
6
PRL IN-
7
LOAD ON/OFF CONT
8
RANGE CONT 1
9
RANGE CONT 0
10
ALARM INPUT
11
TRIG INPUT
12
A COM
13
LOAD ON STATUS
14
RANGE STATUS 1
15
RANGE STATUS 0
16
ALARM STATUS
17
STATUS COM
18
N.C.
19
SHORT SIGNAL OUT
20
SHORT SIGNAL OUT
*1. Valid only when the front panel settings is H range.
*2.
RANGE CONT 0
H range
M range
L range
*3.
RANGE STATUS 0 RANGE STATUS 1
H range
M range
L range
*4. The maximum applied voltage of the photocoupler is 30 V; the maximum current is 8 mA.
6-42 Applied Operation
Table6-9
J1 connector pin arrangement
Can be used in CC, CR, CV, and CP modes
0 V to 10 V correspond to 0 % to 100 % of the rated current (CC mode), rated voltage
(CV mode), or rated power (CP mode).
0 V to 10 V correspond to maximum resistance to minimum resistance (CR mode)
0  to 10 k
mode), rated voltage (CV mode), or rated power (CP mode).
0
to 10 k
resistance to maximum resistance (CR mode)
Current monitor output
10 V f.s (H/L range) and 1 V f.s (M range)
Connected to the negative load input terminal on the rear panel.
Used during master/slave operation. Connected to SUM I MON of the J2 connector.
Used during master/slave operation. Connected to PRL OUT+ of the J2 connector.
Used during master/slave operation. Connected to PRL OUT- of the J2 connector.
Turns on the load with low (or high) TTL level signal
Pulled up the internal circuit to 5 V using 10 k.
External range switch input
Pulled up the internal circuit to 5 V using 10 k
Activates alarm with low TTL level signal input.
Pulled up the internal circuit to 5 V using 10 k.
When paused, clears the pause when a high level TTL signal is applied for 10 s or
longer.
Pulled down the internal circuit to A COM using 100 k.
Connected to the negative load input terminal on the rear panel.
Turns on when load is on. Open collector output by a photocoupler.
Range status output. Open collector output by a photocoupler.
Turns on when an alarm (OVP, OCP, OPP, OHP, REV, or UVP) is activated or when an
external alarm is applied. Open collector output by a photocoupler.
STATUS signal common for pins 13 to 16.
Relay contact output (30 VDC/1 A)
RANGE CONT 1
1
1
1
0
0
1
OFF
OFF
OFF
ON
ON
OFF
Description
correspond to 0 % to 100 % or 100 % to 0 % of the rated current (CC
correspond to maximum resistance to minimum resistance or minimum
*1 *2
.
*4
*4
*4
PLZ-4W

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Plz334wPlz1004wPlz164waPlz664wa