Kikusui PLZ164W User Manual page 178

Plz-4w series
Hide thumbs Also See for PLZ164W:
Table of Contents

Advertisement

Symptom 7: The transmission/reception does not work when you
communicate using the program previously used.
Check Item
Location and Status of the Object
Is the acknowledge message used?
Symptom 8: The setting current is not flowing
Check Item
Location and Status of the Object
Is the LED located inside of the
unit illuminated? See the 8.2,
"Confirming status of the fuse."
Symptom 9: When either PLZ164WA or PLZ664WA is used, the
reverse-connection detection (REV) activates by turning on/off of
the DUT.
Check Item
Location and Status of the Object
Do you connect the DC power
supply and the DUT (an open-
close device such as a switch) in
series ?
8-16 Maintenance and Calibration
Check Result
There is a case that your program targeted at PLZ-4W ROM
version 1.17 or earlier may not work correctly with ROM
version 1.18 or later. In that case, change the Ack setting to
"ON + ^Q".
Precedure of changing
1. Select "1. Configuration" | "3. Interface" |
"RS232C" from the menu.
Yes
2. Press the
select Ack.
3. Press the ENTER key.
"ON + ^Q" is selected. It is impossible to select "ON +
^Q" with the rotary knob. To select ON/OFF, press the
ENTER key again.
Possible Cause
Check Result
Yes
Fuse blow
Possible Cause
Check Result
The reverse voltage is
Yes
applied to the load input
terminal.
Remedy
CURSOR key several times to
Remedy
Immediately stop the use of the
instruments and request for repair
service.
Remedy
Set to avoid the occurrence of
alarm.
See "When the DC power supply
and the DUT are connected in
series, and turning on/off of the
DUT. (PLZ164WA/PLZ664WA
only)" in section 5.2, "Turning
On or Off the Load."
PLZ-4W

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Plz334wPlz1004wPlz164waPlz664wa

Table of Contents