Creating the program
SEQ
No.
: 11
Memo :
Mode : FCC
Ran
g
e : 33A , 15V
Loop : 0003
PREV
NEXT
6-32 Applied Operation
• No.
• Memo
• Range
• Loop
• Last Load
• Last Set
• RPTSTEP
• TIME BASE
• Current setting
• Trigger output
1.
Select sequence edit.
Press the EDIT (SHIFT+A) key to display the program edit screen.
■ Setting the operation of program 11
2.
Select the program number.
Turn the rotary knob to set the program number.
Select 11, because you can only select 11 for a fast sequence. After setting the
program number, press the
3.
Enter a memo.
When adding a memo, turn the rotary knob to enter the characters.
In program 11, enter "Program11". After entering the memo, move the
CURSOR key to move to the next item.
4.
Select the operation mode.
Turn the rotary knob to show the operation mode to be executed.
Select constant current mode "FCC." After setting the operation mode, move
the
CURSOR key to move to the next item.
5.
Sets the range.
Turn the rotary knob to select the current range and voltage range.
Set 33 A - 15 V. After setting the range, move the
the next item.
Program number (11)
Memo (PLZ164W)
Current range-voltage range (33A-15V)
Number of program loops (3)
Load condition at the end (ON)
Current value at the end (1 A)
Last step per loop (15)
Step execution time (1 ms)
Steps 1 to 5: 10 A
Step 5: 5 A
Steps 7 to 10: 10 A
Step 11: 5 A
Steps 12 to 15: 10 A
Step 6
CURSOR key to move to the next item.
CURSOR key to move to
PLZ-4W