A.5.4
I/O Cable (NovAtel part number 01018519, 01019148)
These cables can be used to connect the ProPak6 I/O port. The cables are 2 metres in length, with a
DB9 male connector at one end and tinned and tagged conductors at the other.
The 01019148 cable is similar in function to the 0108519 cable, however each signal is in a twisted pair
with a ground wire to reduce cross talk and improve signal integrity. The 01019148 cable is
recommended when using multiple event lines simultaneously in order to prevent false triggers.
122
Table 20: I/O Cable Wiring Instructions
DB9 Male to
Receiver
P1
Black
P2
Brown
P3
Red
P4
Orange
P5
Yellow
P6
Green
P7
Blue
P8
Violet
P9
White/Grey
Shell
Shield
ProPak6 Installation and Operation User Manual Rev 4
Color Code