Installation
The available power for both COM ports are shared (maximum 1.5 A total in any combination between
the ports). If only one COM port is used, the entire 1.5 A is available to that port. The total peripheral
power current is limited to 1.5 A. Transient currents greater than 1.5 A are clamped by the ProPak6.
Refer to A.2, ProPak6 Specifications on page 111 for baud rates. Refer to the
Reference Manual
2.4

Standard Configuration Installation

Complete the steps below to connect and power a standard ProPak6 configuration.
If using the ProPak6 in a low vibration installation, attach the included mounting
brackets to the ProPak6 prior to cabling. Complete mounting instructions are contained
in the Quick Start Guide included with the ProPak6. Refer to Section 2.7.4, Mounting
the ProPak6 on page 32 for direct mounting instructions.
1. Mount a GNSS antenna (user supplied) on a secure, stable structure with an unobstructed view of
the sky from horizon to horizon. Refer also to Section 2.6.1, Mounting the GNSS Antenna on
page 29.
ProPak6 Installation and Operation User Manual Rev 4
(OM-20000129) for COMVOUT command details.