Chapter 4
4. Obtain the IP address assigned to the ProPak6 receiver by the DHCP server.
log ipstatus once
Make a note of the IP address returned with this log. This value is used later in this
procedure.
5. Confirm that DHCP is enabled. by entering:
log ipconfig once
6. Assign the TCP/IP port number by entering:
icomconfig icom1 tcp :2000
7. Confirm the port number assigned to ICOM1 by entering:
log icomconfig once
8. Save settings the settings by entering:
saveconfig
Issue the SAVEETHERNETDATA ETHA command to ensure port settings are
retained after a reset and automatically used at boot time. The
SAVEETHERNETDATA ETHA command is not applicable to the ICOMCONFIG and
NTRIPCONFIG settings. The SAVEETHERNETDATA ETHA command overrides the
SAVECONFIG command configuration settings.
9. Use the IP address obtained from the IPSTATUS log and the assigned port number. Confirm new
settings (refer to the figure below)..
For information about establishing a connection using NovAtel Connect, refer to the
Quick Start Guide for the product or NovAtel Connect Help.
4.4

Base/Rover Configuration through Ethernet Connectivity

You can use an Ethernet connection to provide communication between a base and rover receiver.
78
ProPak6 Installation and Operation User Manual 4
Ethernet Configuration

Hide quick links: