Technical Data - Siemens S120 Manual

Hide thumbs Also See for S120:
Table of Contents

Advertisement

Supplementary system components and encoder system integration
8.1 Sensor Modules
8.1.2.6

Technical data

Table 8- 5
6SL3055-0AA00-5AAx
Electronics power supply
Voltage
Current (without encoder system)
Current (with encoder system)
Power loss
Specification
Transformation ratio of the resolver (ü)
Excitation voltage on the SMC10 when ü=0.5
Amplitude monitoring threshold (secondary
tracks) of the SMC10
Excitation voltage (cannot be parameterized)
Excitation frequency (synchronized to the current
controller clock cycle)
PE/ground connection
Max. encoder cable length
Weight
Degree of protection
Table 8- 6
Number of
350
Technical data
Max. frequency that can be evaluated (speed)
Resolver
Number of
poles
pole pairs
2-pole
1
4-pole
2
6-pole
3
8-pole
4
Unit
V
DC
A
DC
A
DC
W
V
rms
V
rms
V
rms
kHz
At the housing with M4/1.8 Nm screw
m
kg
Max. speed resolver / motor
8 kHz/125 μsec
4 kHz/250 μsec
120000 rpm
60000 rpm
60000 rpm
30000 rpm
40000 rpm
20000 rpm
30000 rpm
15000 rpm
Value
24 (20,4 ... 28,8)
≤ 0,20
≤ 0,35
≤ 10
0,5
4,1
1
4,1
5 to 16
130
0,45
IP20 or IPXXB
2 kHz/500 μsec
30000 rpm
15000 rpm
10000 rpm
7500 rpm
Manual, (GH6), 04/2014, 6SL3097-4AL00-0BP4
AC Drive

Advertisement

Table of Contents
loading

Table of Contents