Technical Data - Siemens S120 Manual

Hide thumbs Also See for S120:
Table of Contents

Advertisement

8.1.4.8

Technical data

Table 8- 17
Technical data
6SL3055-0AA00-5CA2
Electronics power supply
Voltage
Current (without encoder system)
Current (with encoder system)
Power loss
Encoder system power supply
Voltage
Current
Encoder frequency that can be evaluated
(f
)
encoder
SSI baud rate
PE/ground connection
Weight
Degree of protection
A controller compares the encoder system supply voltage - sensed via the Remote Sense cables - with the reference
1)
supply voltage of the encoder system, and adjusts the supply voltage for the encoder system at the output of the sensor
module until the required supply voltage is obtained directly at the encoder system (only for 5 V encoder system power
supply). Remote Sense only to X520.
See the diagram "Maximum cable length depending on the SSI baud rate for SSI encoders"
2)
AC Drive
Manual, (GH6), 04/2014, 6SL3097-4AL00-0BP4
Supplementary system components and encoder system integration
Unit
Value
V
24 (20,4 ... 28,8)
DC
A
≤ 0,20
DC
A
≤ 0,55
DC
W
≤ 10
V
5 (with or without remote sense)
DC
A
0.35
DC
kHz
≤ 300
kBd
100 - 1000
At the housing with M4/1.8 Nm screw
0,45
IP20 or IPXXB
or V
1)
2)
8.1 Sensor Modules
- 1 V
DC
373