Siemens S120 Manual page 150

Hide thumbs Also See for S120:
Table of Contents

Advertisement

Power Modules
4.3 Power Modules Blocksize (PM340)
PM340
PM340 with integrated line filter
NH fuses
IEC 60947
Rated current
Circuit breaker type designation
IEC 60947
Rated current
Resistance value
ext. braking resistor
Max. cable length
to braking resistor
Line supply connection
L1, L2, L3
Motor connection
U2, V2, W2
DC link connection, connection for
braking resistor
DCP/R1, DCN, R2
PE connection
Max. motor cable length
shielded/unshielded
Degree of protection
Weight
Rated power of a typical standard induction motor at 400 V 3 AC
1)
The input current depends on the motor load and line impedance. The input currents apply for a load with the type rating
2)
(based on I
) for a line impedance corresponding to u
rated
Max. motor cable length 25 m (shielded) for PM340 Power Modules with integrated line filter to maintain the limit values
3)
of EN 61800-3 Category C2.
Table 4- 27
Technical data PM340, FSD (3 AC 380 V to 480 V ±10 %)
PM340
PM340 with integrated line filter
Output current
Rated current I
n
Base-load current I
H
for S6 operation (40 %) l
Peak current l
max
Type rating
1)
on basis of I
n
on basis of I
H
Rated pulse frequency
Power loss
Cooling air requirement
Sound pressure level L
pA
150
6SL3210-
6SL3210-
A
A
Ω
m
m
3)
kg
6SL3210-
6SL3210-
A
A
A
s6
A
kW
kW
kHz
kW
m
/s
3
(1 m)
dB(A)
1SE21-8UA0
1SE22-5UA0
1SE21-8AA0
1SE22-5AA0
3NA3810
3NA3814
25
35
3RV1031-4EA10
3RV1031-4FA10
22 ... 32
28 ... 40
> 56
> 56
15
15
Screw terminals for cable cross-section 2.5 ... 10 mm
On housing with M5 screw
50 / 75
IP20 or IPXXB
6,5
6,5
= 1%.
k
1SE23-8UA0
1SE24-5UA0
1SE23-8AA0
1SE24-5AA0
38
45
33
40
49
58
64
76
18,5
22
15
18,5
4
4
0,38
0,51
0,022
0,022
< 60
< 60
Manual, (GH6), 04/2014, 6SL3097-4AL00-0BP4
1SE23-2UA0
1SE23-2AA0
3NA3817
40
3RV1031-4HA10
40 ... 50
> 56
15
2
6,5
1SE26-0UA0
1SE26-0AA0
60
48
78
90
30
22
4
0,69
0,039
< 60
AC Drive

Advertisement

Table of Contents