Electrical Connection - Siemens S120 Manual

Hide thumbs Also See for S120:
Table of Contents

Advertisement

6.1.1.5

Electrical connection

Electrical connection of PM240-2 Power Modules
Note
Approved cables
Use only 75° C copper cables.
Table 6- 12
Securing the connection cables to the motor reactor
Frame size
Max. cross-section that
can be connected
FSA
4 mm
2
FSB
10 mm
2
FSC
16 mm
2
Electrical connection of PM340 Power Module
Figure 6-13
AC Drive
Manual, (GH6), 04/2014, 6SL3097-4AL00-0BP4
Terminal connection
Tightening torque
0.6 ... 0.8 Nm
1.5 ... 1.8 Nm
2.0 ... 4.0 Nm
PE connection
Motor reactor
Electrical connection
Motor-side power components
PE connection
Fastening
M4 screw
M5 screw
M5 screw
6.1 Blocksize
Tightening torque
3 Nm
5 Nm
5 Nm
227