Motor-side power components
6.2 Chassis
6.2.1.4
Technical data
Table 6- 18
Technical data, motor reactors
Order number
Suitable for
Power Module
Unit rating of the Power
Module
Rated current
Power loss
- at 50 Hz
- at 150 Hz
Connections
- to the Motor Module (1U1,
1V1, 1W1)
- to the load (1U2, 1V2, 1W2)
- PE
Max. permissible cable length
between motor reactor and
motor
- with 1 motor reactor
- with 2 motor reactors in
series
Degree of protection
Dimensions
Width
Height
Depth
Weight
234
6SL3000-
2BE32-1AA0
6SL3310-
1TE32-1AAx
kW
110
A
210
kW
0,436
kW
0,486
M10
M10
M8
m
m
IP00
mm
300
mm
285
mm
257
kg
66
2BE32-6AA0
2BE33-2AA0
1TE32-6AAx
1TE33-1AAx
132
160
260
310
0,454
0,422
0,5
0,47
M10
M10
M10
M10
M8
M8
300 (shielded) / 450 (unshielded)
525 (shielded) / 787 (unshielded)
IP00
IP00
300
300
315
285
277
257
66
66
Manual, (GH6), 04/2014, 6SL3097-4AL00-0BP4
2BE33-8AA0
2BE35-0AA0
1TE33-8AAx
1TE35-0AAx
200
250
380
490
0,447
0,448
0,5
0,5
M10
M12
M10
M12
M8
M8
IP00
IP00
300
300
285
365
277
277
73
100
AC Drive