X23 Htl/Ttl/Ssi Encoder Interface - Siemens S120 Manual

Hide thumbs Also See for S120:
Table of Contents

Advertisement

7.3.2.3

X23 HTL/TTL/SSI encoder interface

Table 7- 3
X23 HTL/TTL/SSI encoder interface
Pin
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Connector type
15-pin Sub-D socket
Measuring current via temperature sensor connection: 2 mA
NOTICE
Risk of motor overheating for incorrectly connected KTY temperature sensor
A KTY temperature sensor connected with incorrect polarity cannot detect if the motor
overheats.
• Make sure that you connect the KTY temperature sensor with the correct polarity.
Note
There are two ways of connecting the temperature sensor:
1. via X120, terminals 1 and 2
2. via X23, pins 1 and 8
AC Drive
Manual, (GH6), 04/2014, 6SL3097-4AL00-0BP4
Control Units, Control Unit Adapters and operating components
Signal name
+Temp
SSI_CLK
SSI_XCLK
P encoder 5 V / 24 V
P encoder 5 V / 24 V
P_Sense
GND
M (-Temp)
M_Sense
RP
RN
BN
BP
AN_SSI_XDAT
AP_SSI_DAT
7.3 Control Unit CU310-2 PN (PROFINET)
Technical data
KTY or PTC input
SSI clock, positive
SSI clock, negative
Encoder power supply
Sense input, encoder power supply
Ground, encoder power supply
Ground for KTY or PTC
Ground sense input
R track positive
R track negative
B track negative
B track positive
A track negative / SSI data negative
A track positive / SSI data positive
265