M8540, M9540, WSM
[4] CONTROL VALVE
Removing Control Valve
1. Remove the E-shaped stopper (2).
2. Remove the control valve mounting screws.
3. Remove the control valve (1).
NOTE
• Do not loosen adjusting section at the end of the spool
unless necessary.
(When reassembling)
• Be sure to fit the O-rings.
Control valve mounting
Tightening torque
screw
Length (L)
Factory spec.
Adjusting Spool Joint
1. Measure the length (L).
2. If the measurement is not within the factory specifications, loosen
the lock nut (4) and adjust by the spool link (3).
(1) Control Valve
(2) E-shaped Stopper
(3) Spool Link
8-S28
HYDRAULIC SYSTEM
19.6 to 23.5 N·m
2.0 to 2.4 kgf·m
14.5 to 17.4 lbf·ft
85.8 to 86.2 mm
3.38 to 3.39 in.
(4) Lock Nut
(5) O-ring
W1019759
KiSC issued 09, 2008 A