M8540, M9540, WSM
PTO Speed Display Mode Switching (Setting Mode)
1. While pressing the PTO/Hour meter select switch (1), turn the
key switch to "ON" position.
The current numerical code starts flashing.
2. Each time the PTO/Hour meter select switch (1) is pressed, the
code changes in the order of [1] → [2] → [3] → [4] → [5] → [1].
Select the appropriate code according to the table below.
3. Press and hold the PTO/Hour meter select switch (1) longer than
2 seconds. The setting is put in memory, and the LCD monitor
(2) goes back to the PTO speed display mode.
4. Turn the key switch to "OFF" position to exit.
NOTE
• The setting will be cancelled if the key switch is turned OFF
halfway in the procedure.
Numerical code
1
540 (Single speed)
540 (Dual speed PTO kit,
2
interchangeable type)
1000 (Dual speed PTO kit,
3
interchangeable type)
540 / 540E (2 Speed PTO, gear shift
4
type)
540 / 1000 (2 Speed PTO, gear shift
5
type)
(1) PTO/Hour Meter Select Switch
(2) LCD Monitor
9-S20
ELECTRICAL SYSTEM
-1
PTO speed (min
(rpm))
(A) Procedure to enter the PTO speed
display mode switching
(B) Procedure to select numerical
code
(C) Procedure to put in memory
W1021843
KiSC issued 09, 2008 A