Anritsu MT9083 Series Operation Manual page 67

Access master remote control
Table of Contents

Advertisement

4.4.4 SENSe:CONCheck? Command
Syntax:
SENSe:CONCheck?
Parameters:
None
Description:
Queries if connection check option is ON.
Example:
sens:conc? --- 1<END>
Response:
Possible response values:
1 = Connection check is ON.
0 = Connection check is OFF.
Errors:
None
4.4.5 SENSe:CONCheck Command
Syntax:
SENSe:CONCheck<wsp><value>
Parameters:
<value>
Boolean value
1 or on = Connection check is ON.
0 or off = Connection check is OFF.
Description:
Sets Connection Check option ON or OFF.
Example:
sens:conc ON<END>
Response:
NONE
Errors:
(–200, "std_execGen, Test is Active")
(–104, "std_wrongParamType, Data Type Error")
4.4.6 SENSe:LIVCheck? Command
Syntax:
SENSe:LIVCheck?
Parameters:
None
Description:
Queries if live fiber check option is ON.
Example:
sens:livc? --- 1<END>
Response:
Possible response values:
1 = Live fiber check is ON.
0 = Live fiber check is OFF.
Errors:
None
4.4