Anritsu MT9083 Series Operation Manual page 65

Access master remote control
Table of Contents

Advertisement

4.3.14 SOURce:PULSe:ENHanced Command
Syntax:
SOURce:PULSe:ENHanced<wsp><value>
Parameters:
<value>
Boolean format
Range: 1|0.
Description:
Set current pulse width's enhanced mode.
Example:
sour:puls:enh 0
Response:
None
Errors:
(–200, "std_execGen, Test is Active")
(–104, "std_wrongParamType, Data Type Error")
(–224, "std_illegalParmValue, Invalid Parameter Value")
4.3.15 SOURce:PULSe:ENHanced? Command
Syntax:
SOURce:PULSe:ENHanced?
Parameters:
None
Description:
Query current pulse width's enhanced mode flag.
Example:
sour:puls:enh? --- 1<END>
Response:
Boolean value of the enhanced mode flag
Errors:
None
4.3.16 SOURce:AVERages:TIMe? Command
Syntax:
SOURce:AVERages:TIMe?
Parameters:
None
Description:
Queries number of seconds that have been set for the next test in manual mode.
Example:
sour:aver:tim? --- 120<END>
Response:
Number of seconds set to run the test.
Errors:
None
4.3.17 SOURce:AVERages:TIMe Command
Syntax:
SOURce:AVERages:TIMe<wsp><value>
Parameters:
<value>
Integer format
Range: 1 – 3600.
Description:
Sets number of seconds for the test duration for the next test in manual mode.
Example:
sour:aver:tim 120<END>
Response:
None
Errors:
(–200, "std_execGen, Test is Active")
(–224, "std_illegalParmValue, Invalid Parameter Value")
4.3
SOURce Subsystem Commands
4
4-13

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents